American College of Radiology
ACR Appropriateness Criteria®

Pretreatment Planning of Invasive Cancer of the Cervix

Variant 1: FIGO stage 1b1, tumor size <4 cm.
Procedure Appropriateness Category SOE Adult RRL Peds RRL Rating Median Final Tabulations
1 2 3 4 5 6 7 8 9
FDG-PET/CT whole body Usually appropriate ☢☢☢☢ 10-30 mSv 8 n/a 0 0 0 0 0 0 0 0 0
MRI pelvis without and with IV contrast Usually appropriate O 0 mSv O 0 mSv [ped] 8 n/a 0 0 0 0 0 0 0 0 0
MRI pelvis without IV contrast May be appropriate O 0 mSv O 0 mSv [ped] 6 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis with IV contrast May be appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 5 n/a 0 0 0 0 0 0 0 0 0
Radiography chest May be appropriate ☢ <0.1 mSv ☢ <0.03 mSv [ped] 4 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis without IV contrast Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US abdomen Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US pelvis transabdominal Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US pelvis transvaginal Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis without and with IV contrast Usually not appropriate ☢☢☢☢ 10-30 mSv ☢☢☢☢☢ 10-30 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Tc-99m bone scan whole body Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Fluoroscopy contrast enema Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Fluoroscopy intravenous urography Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢ 0.3-3 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Variant 2: FIGO stage Ib2, tumor size >4 cm.
Procedure Appropriateness Category SOE Adult RRL Peds RRL Rating Median Final Tabulations
1 2 3 4 5 6 7 8 9
FDG-PET/CT whole body Usually appropriate ☢☢☢☢ 10-30 mSv 9 n/a 0 0 0 0 0 0 0 0 0
MRI pelvis without and with IV contrast Usually appropriate O 0 mSv O 0 mSv [ped] 9 n/a 0 0 0 0 0 0 0 0 0
MRI pelvis without IV contrast May be appropriate O 0 mSv O 0 mSv [ped] 6 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis with IV contrast May be appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 5 n/a 0 0 0 0 0 0 0 0 0
Radiography chest May be appropriate ☢ <0.1 mSv ☢ <0.03 mSv [ped] 5 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis without IV contrast Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US abdomen Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US pelvis transabdominal Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US pelvis transvaginal Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis without and with IV contrast Usually not appropriate ☢☢☢☢ 10-30 mSv ☢☢☢☢☢ 10-30 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Tc-99m bone scan whole body Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Fluoroscopy contrast enema Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Fluoroscopy intravenous urography Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢ 0.3-3 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Variant 3: FIGO stage >Ib.
Procedure Appropriateness Category SOE Adult RRL Peds RRL Rating Median Final Tabulations
1 2 3 4 5 6 7 8 9
FDG-PET/CT whole body Usually appropriate ☢☢☢☢ 10-30 mSv 9 n/a 0 0 0 0 0 0 0 0 0
MRI pelvis without and with IV contrast Usually appropriate O 0 mSv O 0 mSv [ped] 9 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis with IV contrast Usually appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 7 n/a 0 0 0 0 0 0 0 0 0
CT chest with IV contrast May be appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 6 n/a 0 0 0 0 0 0 0 0 0
MRI pelvis without IV contrast May be appropriate O 0 mSv O 0 mSv [ped] 6 n/a 0 0 0 0 0 0 0 0 0
CT chest without IV contrast May be appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 4 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis without IV contrast Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
Tc-99m bone scan whole body Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US abdomen Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US pelvis transabdominal Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
US pelvis transvaginal Usually not appropriate O 0 mSv O 0 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
Radiography chest Usually not appropriate ☢ <0.1 mSv ☢ <0.03 mSv [ped] 2 n/a 0 0 0 0 0 0 0 0 0
CT abdomen and pelvis without and with IV contrast Usually not appropriate ☢☢☢☢ 10-30 mSv ☢☢☢☢☢ 10-30 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
CT chest without and with IV contrast Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Fluoroscopy contrast enema Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢☢ 3-10 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Fluoroscopy intravenous urography Usually not appropriate ☢☢☢ 1-10 mSv ☢☢☢ 0.3-3 mSv [ped] 1 n/a 0 0 0 0 0 0 0 0 0
Appendix Key

A more complete discussion of the items presented below can be found by accessing the supporting documents at the designated hyperlinks.

Appropriateness Category:The panel’s recommendation for a procedure based on the assessment of the risks and benefits of performing the procedure for the specified clinical scenario.

SOE: Strength of Evidence. The assessment of the amount and quality of evidence found in the peer reviewed medical literature for an appropriateness recommendation.

  • References: The citation number and PMID for the reference(s) associated with the recommendation.
  • Study Quality: The assessment of the quality of an individual reference based on the number of study quality elements described in the reference.

RRL: Relative Radiation Level. A population based assessment of the amount of radiation a typical patient may be exposed to during the specified procedure.

Rating: The final rating (1-9 scale) for the procedure as determined by the panel during rating rounds.

Median: The median rating (1-9 scale) for the procedure as determined by the panel during rating rounds.

Final tabulations: A histogram showing the number of panel members who rated the procedure as noted in the column heading (ie, 1, 2, 3, etc.).

Additional supporting documents about the AC methodology and processes can be found at www.acr.org/ac.